TECHNICS · heater ···

The heater is an essential part of each cold spray system.
Heating up the gas to moderate temperatures is
increasing the flow ability and ends up
in a significant increased velocity of the gas.

Heaters are available with 17 KW, 34 KW and 47 KW for the Kinetics ® 4000 System and with 52 KW and 85 KW for the Kinetics ® 8000 System.
System
Nitrogen
Helium
max. Pressure
Materials
Flow
         
Kinetiks 4000/17-S
550°C
-
40 bar
e.g. Zinc, Aluminium
72 m³/h (N2);
160 m³/h (He)
Kinetiks 4000/34-X
800°C (2)
600°C (1)
40 bar
e.g. Nickel, Copper
72 m³/h (N2);
160 m³/h (He)
Kinetiks 4000/47-M
800°C (2)
800°C (1)
40 bar
high end Niobium
72 m³/h (N2);
160 m³/h (He)
Kinetiks 8000/52-KW-S-N2
950°C
-
40 bar
high end like
Ti6Al4V
72 m³/h (N2)
     
Kinetiks 8000/52-KW-S2-HP-N2
950°C
-
40 bar
high end like
Ti6Al4V
160 m³/h (N2)
     
(1) optional, (2) obligatory