The heater is an essential part of each cold spray system.
Heating up the gas to moderate temperatures is
increasing the flow ability and ends up
in a significant increased velocity of the gas.
|
|
| Heaters are available with 17 KW, 34 KW and 47 KW for the Kinetics ® 4000 System and with 52 KW and 85 KW for the Kinetics ® 8000 System.
|
|
|
|
|
|
|
|
System |
Nitrogen |
Helium |
max. Pressure |
Materials |
Flow |
| |
|
|
|
|
|
Kinetiks 4000/17-S |
550°C |
- |
40 bar |
e.g. Zinc, Aluminium |
72 m³/h (N2);
160 m³/h (He) |
|
|
|
|
|
|
Kinetiks 4000/34-X |
800°C (2) |
600°C (1) |
40 bar |
e.g. Nickel, Copper |
72 m³/h (N2);
160 m³/h (He) |
|
|
|
|
|
|
Kinetiks 4000/47-M |
800°C (2) |
800°C (1) |
40 bar |
high end Niobium |
72 m³/h (N2);
160 m³/h (He) |
|
|
|
|
|
|
Kinetiks 8000/52-KW-S-N2 |
950°C |
- |
40 bar |
high end like
Ti6Al4V |
72 m³/h (N2)
|
| |
|
|
|
|
|
Kinetiks 8000/52-KW-S2-HP-N2 |
950°C |
- |
40 bar |
high end like
Ti6Al4V |
160 m³/h (N2)
|
| |
|
|
|
|
|
|
|
(1) optional, (2) obligatory |
|
|